Final Report F100, Nuremberg Germany, 20 Jan 2015
Final Report F100, Nuremberg Germany, 20 Jan 2015
On 20 January 2015, The APU of a Fokker 100 being routinely de-iced prior to departing Nuremburg oversped as a result of the ignition of ingested de-icing fluid in the APU. This led to its explosive uncontained failure as the result of which ejected debris entered the aft cabin and smoke occurred. No occupants were injured and all were promptly disembarked. The Investigation found that the de-icing contractor involved had not followed manufacturer-issued aircraft-specific de-icing procedures and in the continued absence of any applicable safety regulatory oversight of ground de-icing activity, corresponding Safety Recommendations were made.