Final Report E195 (G-FBEJ) Exeter UK, 28 Feb 2019
Final Report E195 (G-FBEJ) Exeter UK, 28 Feb 2019
On 28 February 2019, an Airbus A320 abandoned takeoff from Exeter when fight deck fumes/smoke accompanied thrust applied against the brakes. When informed of similar conditions in the cabin, the Captain ordered an emergency evacuation. Some passengers using the overwing exits re-entered the cabin after becoming confused as to how to leave the wing. The Investigation attributed the fumes to an incorrectly-performed engine compressor wash arising in a context of poorly-managed maintenance and concluded that guidance on overwing exit use had been inadequate and that the 1.8 metre certification height limit for exits without evacuation slides should be reduced.