Final Report - A388 smoke in lavatory, 300NM NE from Singapore, 31 Jan 2011

Final Report - A388 smoke in lavatory, 300NM NE from Singapore, 31 Jan 2011

Publication info
Author
AAIB (Singapore)
Category
Accident Reports Airworthiness

On 31 January 2011, a Singapore Airlines Airbus A380-800 was in the cruise when there was sudden loud noise and signs of associated electrical smoke and potential burning in a toilet compartment with a corresponding ECAM smoke alert. After a fire extinguisher had been discharged into the apparent source, there were no further signs of fire or smoke. Subsequent investigation found signs of burning below the toilet floor and it was concluded that excessive current caused by a short circuit which had resulted from a degraded cable had been the likely cause, with over current protection limiting the damage caused by overheating.