Final Report A320 (G-EZOC) en-route NW Greece, 29 September 2017

Final Report A320 (G-EZOC) en-route NW Greece, 29 September 2017

Publication info
Author
AAIASB Greece
Category
Accident Reports Non Combustion-related Fumes Airworthiness
Date of publication
21/01/2021

On 29 September 2017, the crew of an Airbus A320 detected a smell of burning plastic and simultaneously observed black smoke entering the flight deck near the right side rudder pedals. Completion of appropriate response procedures reduced the smoke and a diversion to Athens with a MAYDAY declared was without further event. The origin of the smoke and fumes was traced to the failure of the static inverter which was part of a batch which had been previously notified as faulty but not identified as such by the aircraft operator’s maintenance organisation which has since modified its relevant procedures. 

SKYbrary Partners:

Safety knowledge contributed by: